As the title says.
On the Windows RC1 build
The name and description seem to imply both should change, but only P changes.
This is the intended behavior. PD balance slider changes the ratio between P and D. You could change either P or D to affect that ratio, we chose to only change P. Changing both would change D and we don't want that because of how D is affected by and affects noise levels. That's why there is a P and D gain slider which moves both up or down.
Description fits the slider in my opinion really good. If you think otherwise, could you point it out?
@IvoFPV the description is not bad but can be misleading as happened to Knifa. Maybe "P to D ballance" will make easier to understand why is P only moving. Just a suggestion though
After playing around I did figure out what was meant. :smile:
And I get what you mean --- it makes sense to just change one rather than changing one up, and the other down.
I like the suggestion of naming it "P to D Balance" instead, though we're probably splitting hairs at this point.
We can do that. If it makes it clearer to what it does at least to someone it is a good change 馃憤
This issue / pull request has been automatically marked as stale because it has not had recent activity. It will be closed if no further activity occurs within a week.
Automatically closing as inactive.
Most helpful comment
@IvoFPV the description is not bad but can be misleading as happened to Knifa. Maybe "P to D ballance" will make easier to understand why is P only moving. Just a suggestion though