Marlin: [BUG] G33 P10 produces "Unknown command" on Delta [Marlin 2.0.5.4]

Created on 20 Jul 2020  路  4Comments  路  Source: MarlinFirmware/Marlin

Bug Description

After upgrading to Marlin 2.0.5.4 I am no longer able to use G33 for Delta Auto Calibration. This worked on 2.0.5.3
Also, the EEPROM doesn't show it's values any longer when connecting to the machine with a host.

My Configurations

M2054_mar.zip

Steps to Reproduce

I have used the Delta example config that was downloaded from Github

  1. Send: G33 P10

Expected behavior:

Delta Auto Calibration

Actual behavior:

SENDING:G33 P10
echo:Unknown command: "G33 P10"

Additional Information

SKR 1.3
Piezo leveling (confirmed working)

All 4 comments

g3 needs DELTA_AUTO_CALIBRATION

// uncomment to add G33 Delta Auto-Calibration (Enable EEPROM_SETTINGS to store results)
//#define DELTA_AUTO_CALIBRATION

The settings your referring to are only displayed on SERIAL_PORT not SERIAL_PORT_2 and you have SERIAL_PORT connected to a touch screen

This Issue Queue is for Marlin bug reports and development-related issues, and we prefer not to handle user-support questions here. (As noted on this page.) For best results getting help with configuration and troubleshooting, please use the following resources:

After seeking help from the community, if the consensus points to a bug in Marlin, then you should post a bug report.

This issue has been automatically locked since there has not been any recent activity after it was closed. Please open a new issue for related bugs.