After upgrading to Marlin 2.0.5.4 I am no longer able to use G33 for Delta Auto Calibration. This worked on 2.0.5.3
Also, the EEPROM doesn't show it's values any longer when connecting to the machine with a host.
I have used the Delta example config that was downloaded from Github
Expected behavior:
Delta Auto Calibration
Actual behavior:
SENDING:G33 P10
echo:Unknown command: "G33 P10"
SKR 1.3
Piezo leveling (confirmed working)
g3 needs DELTA_AUTO_CALIBRATION
// uncomment to add G33 Delta Auto-Calibration (Enable EEPROM_SETTINGS to store results)
//#define DELTA_AUTO_CALIBRATION
The settings your referring to are only displayed on SERIAL_PORT not SERIAL_PORT_2 and you have SERIAL_PORT connected to a touch screen
This Issue Queue is for Marlin bug reports and development-related issues, and we prefer not to handle user-support questions here. (As noted on this page.) For best results getting help with configuration and troubleshooting, please use the following resources:
After seeking help from the community, if the consensus points to a bug in Marlin, then you should post a bug report.
This issue has been automatically locked since there has not been any recent activity after it was closed. Please open a new issue for related bugs.