Ironos: Incorrect power meter display v2.06-RC5

Created on 18 Jul 2019  路  6Comments  路  Source: Ralim/IronOS

  • I'm submitting a ...

    • [x] Bug report

The power display fluctuates around one watt when warming up. When the temperature reaches, the indicator shows zero or a very low value.
Powered at 19 Volts.

Next Release bug

Most helpful comment

Same problem here with an TS80.

Using a Keweisi KWS-MX18 for power supply monitoring an a charmast W2009P powerbank wich is able to supply 12V. The TS80 is also set to this value.

First the TS80 is only using 9V, this is something I can see on the powerbank, the KWS and the iron itself.

Second when heating up, the iron is telling me it uses about 30W, the KWS-MX18 is telling me it only uses about 18W. After the heat of 450掳 is reached, it will not stop heating and hits over 480掳, the iron is telling me its using between 0W-90W, the KWS is telling about 7W. After some seconds it will slowly decrease the temp around the 450掳.

All 6 comments

Same problem here with an TS80.

Using a Keweisi KWS-MX18 for power supply monitoring an a charmast W2009P powerbank wich is able to supply 12V. The TS80 is also set to this value.

First the TS80 is only using 9V, this is something I can see on the powerbank, the KWS and the iron itself.

Second when heating up, the iron is telling me it uses about 30W, the KWS-MX18 is telling me it only uses about 18W. After the heat of 450掳 is reached, it will not stop heating and hits over 480掳, the iron is telling me its using between 0W-90W, the KWS is telling about 7W. After some seconds it will slowly decrease the temp around the 450掳.

Same, TS100 never shows over 3.1W even in boost mode. 24V 6A notebook style AC adaptor.

Nothing new on that? I will go back to the old firmware es the iron starts smelling after it got over 480掳.. :(

It's purely an aesthetic issue with me forgetting to change a divisor before the number is shown. It doesn't affect operation.

The irons tip is only rated to 400C for main use, and 450C is pushing it to the limit.
You shouldnt use the tip above 380C for prolonged use.

This should have been fixed in the latest release

2.07: Just checked it out. Can confirm, it's working again, thanks for your hard work! <3